The parameters can be adjusted according to the process requirements, but not as the acceptance standard. The detailed specifications will be described in the technical proposal and agreement.
Parameter/Model | VHP-444 | VHP-445 | VHP-446 | VHP-554 | VHP-555 |
Effective hot zone size W×H×L (mm) | 400×400×400 | 500×500×600 | 400×400×600 | 500×500×400 | 500×500×500 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment |
Max. temperature (°C) | 2000/2400/2600 |
Loading pressure (T) | 30-200 | 30-200 | 30-200 | 30-300 | 30-300 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 | 2-10 |
Parameter/Model | VHP-556 | VHP-666 (A/B) | VHP-777 | VHP-888 | VHP-9910 |
Effective hot zone size W×H×L (mm) | 500×500×600 | 600×600×600 | 700×700×700 | 800×800×800 | 900×900×1000 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment |
Max. temperature (°C) | 2000/2400/2600 |
Loading pressure (T) | 30-300 | 50-400 | 50-500 | 100-700 | 200-800 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 | 2-10 |
Parameter/Model | VHP-101010 | VHP-121206 | VHP-131314 | VHP-141412 |
Effective hot zone size W×H×L (mm) | 1000×1000×1000 | 1200×1200×600 | 1300×1300×1400 | 1400×1400×1200 |
Heating Power (kW) | Determine the power value based on the maximum temperature of the ordered equipment |
Max. temperature (°C) | 2000/2400/2600 |
Loading pressure (T) | 200-1000 | 300-1500 | 300-2000 | 300-2000 |
Temperature Uniformity (°C) | ±5 | ±5 | ±5 | ±5 |
Vacuum degree (Pa) | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 | 5/4×10-3/6×10-4 |
Pressure Increasing Rate (Pa/h) | ≤0.26 | ≤0.26 | ≤0.26 | ≤0.26 |
≤0.65 | ≤0.65 | ≤0.65 | ≤0.65 |
Quantity pressing plate | Single/Multi | Single/Multi | Single/Multi | Single/Multi |
Parallelism of upper and lower plate (mm) | ≤0.08 | ≤0.08 | ≤0.08 | ≤0.08 |
Pressure accuracy | ≤±0.5% | ≤±0.5% | ≤±0.5% | ≤±0.5% |
full range ± 0.5T | full range ± 0.5T | full range ± 0.5T | full range ± 0.5T |
Displacement accuracy (mm) | H±0.05 | H±0.05 | H±0.05 | H±0.05 |
Gas cooling pressure (bar) | 2-10 | 2-10 | 2-10 | 2-10 |
1.Expect manually loading and unloading process, others are asthmatically, digitally and intelligent.
2.With 2 bar-15 bar gas system for external circle fast cooling, ensure the product cooling down quickly and efficiently.
3.Not only work under vacuum, also can under positive hydrogen and argon atmosphere. It's good for pressing the similar power such as CuZnSn.
4.Hot-zone be simulation calculated with precise accurate temperature uniformity, the heating elements and insulation be modulation design.
5.There is a pressing frame device with one or more accurate hydraulic cylinders on both upper and bottom for dual pressing.
6.The surface of the ram accuracy can be ±5um.
7.Equip with pressure and weight sensor made-in-Germany to make sure the pressing force outlet accuracy.
8.Equip with position sensor made-in-Germany to make sure the position accuracy.
9.The ram can be sustain 12 hours at 2400°C with accurate press force.
10.Pressing force value, displacement value will be curved and digital showed on the computer screen.
11.Single-way pressure and double-way pressure ram.
12.Pressing control ways: with hydraulic servo-motor proportional valve flow control.
13.Insulation can be graphite or metal.
14.Loading pressure can be 30T, 50T, 100T, 200T, 400T, 500T, 800T, 1000T, 2000T.
15.Temperature can be 1500°C, 1800°C, 2000°C, 2300°C, 2400°C, 2500°C.
16.Ram material can be isostatic pressing graphite or TZM alloy.
1. Furnace door type: on-line/off-line, vertically up and down, rotating
2. Vacuum pump and gauge: Foreign brand/high-quality Chinese brand
3.PLC: OMRON/Siemens/Mitsubishi
4. Temperature controller: SHIMADEN/EUROTHERM/Honeywell
5. Thermocouple: S type, K type, K type
6. Recorder: Paperless recorder/paper recorder
7. HMI: Simulation screen/Touch screen with industry computer
8. Electric component: high-quality Chinese brand/Siemens